100 Psion Teklogix Mobile Devices SDK Developers Guide
Chapter 14: Scanners
Configuring Bar Code Symbologies
Trioptic Code Settings
HHP Imager
These settings apply only to the HHP imager acting as a decoded scanner using the Code 39
symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
14.3.3.3 Trioptic Code Settings
HHP Imager
These settings apply only to the HHP imager acting as a decoded scanner using the Trioptic Code
symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
•Tab
Barcodes
Scanner:
Decoded (HHP)
Menu Item
Code 39
Scanner Setting Key: Barcode\C39\HHP
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 1 Enabled
Start Stop Char 0 = off 1 = on 0 Start/Stop Transmit
Check Char 0 2 0 Check Char
Length Min 0 48 0 Minimum Length
Length Max 0 48 48 Maximum Length
Append 0 = off 1 = on 0 Append
Pharmaceutical 0 = off 1 = on 0 Pharmaceutical
Full Ascii 0 = off 1 = on 0 Full ASCII
•Tab
Barcodes
Scanner:
Decoded (HHP)
Menu Item
Trioptic Code
Scanner Setting Key: Barcode\Trioptic\HHP
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 0 Enabled